EX4300 Specifications
Physical Specifications
Backplane
320 Gbps Virtual Chassis interconnect to combine up to 10 units
as a single logical device
Uplink Module Options
Dual-mode 4-port 10GbE SFP+/4-port GbE SFP module with
pluggable SFP+/SFP optics
Power Options
Power supplies: Autosensing; 100-120 V/200-240 V; AC 350 W
AFO, 350 W AFI, 715 W AFO, and 1,100 W AFO dual load-sharing
hot-swappable internal redundant power supplies
Maximum current inrush: 50 amps
DC power supply: 550 W DC AFO and 550 W DC AFI; input voltage
range 36-72 V; dual input feed, dual load-sharing hot-swappable
internal redundant power supplies
Minimum number of PSUs required for fully loaded chassis: 1 per
switch
Dimensions (W x H x D)
17.41 x 1.72 x 16.43 in (44.21 x 4.32 x 41.73 cm)
Desktop installation width noted above, rack-mount width is
17.5 in (44.5 cm)
Height: 1 rack unit (1 U)
System Weight
EX4300 switch (no power supply or fan module): 13 lb (5.9 kg)
EX4300 switch (with single power supply and two fan modules):
16.1 lb (7.3 kg)
350 W AC power supply: 2.4 lb (1.1 kg)
715 W AC power supply: 2.4 lb (1.1 kg)
1100 W AC power supply: 2.4 lb (1.1 kg)
550 W DC power supply: 2.4 lb (1.1 kg)
SFP+ uplink module: 0.44 lb (0.2 kg)
Fan module: 0.33 lb (0.15 kg)
Environmental Ranges
Operating temperature: 32° to 113° F (0° to 45° C)
Storage temperature: -40° to 158° F (-40° to 70° C)
Operating altitude: up to 10,000  (3,049 m)
Non-operating altitude: up to 16,000  (4,877 m)
Relative humidity operating: 10% to 85% (noncondensing)
Relative humidity non-operating: 0% to 95% (noncondensing)
Cooling
Field-replaceable fans: 2
Switch remains operational even if one fan fails
Airflow: PSU-7.5 CFM, fan-22 CFM
Total maximum airflow throughput with two power supplies:
59 CFM
Hardware Specifications
Switching Engine Model
Store and forward
Memory
DRAM: 2 GB with Error Correcting Code (ECC)
Flash: 2 GB
CPU
1.5 GHz Dual-Core PowerPC CPU
GbE Port Density per System
24P/24T: 28 (24 host ports + four-port 1/10GbE uplink module)
48P/48T: 52 (48 host ports + four-port 1/10GbE uplink module)
10GbE port density per system (all models): 4 (uplink module)
40GbE port density per system (all models): 4
Supported Optics
GbE SFP optic/connector type: LC SFP fiber supporting SX
(multimode), LX (single-mode)
10GbE SFP+ optic/connector type: 10GbE SFP+ LC connector, SR
(multimode), USR (multimode), LR (single-mode), ER (single-
mode), LRM (multimode), and DAC (direct-attach copper)
40 GbE QSFP+ optic/connector type: 40GbE QSFP+ LC connector
type, SR (multimode), DAC (direct-attach copper)
Physical Layer
Time Domain Reflectometry (TDR) for detecting cable breaks and
shorts: 24P/24T and 48P/48T only
Auto medium-dependent interface/medium-dependent interface
crossover (MDI/MDIX) support: 24P/24T and 48P/48T only (all
ports)
Port speed downshi/setting maximum advertised speed on
10/100/1000BASE-T ports: 24P/24T and 48P/48T only, on all
ports
Digital optical monitoring for optical ports
Packet Switching Capacities (Maximum with 64 Byte Packets)
24P/24T: 448 Gbps
48P/48T: 496 Gbps
Soware Specifications
Security
MAC limiting (per port and per VLAN)
Allowed MAC addresses configurable per port
Dynamic ARP inspection (DAI)
IP source guard
Local proxy ARP
Static ARP support
DHCP snooping
Captive portal
Persistent MAC address configurations
Distributed denial of service (DDoS) protection (CPU control path
flooding protection)
Layer 2/Layer 3 Throughput (Mpps) (Maximum with
64 Byte Packets)
24P/24T: 333 Mpps (wire speed)
48P/48T: 369 Mpps (wire speed)
Layer 2 Switching
Maximum MAC addresses per system: 64,000
Jumbo frames: 9,216 Bytes
Number of VLANs: 4,093
Virtual Spanning Tree (VST) instances: 510
Port-based VLAN
MAC-based VLAN
Voice VLAN
Physical port redundancy: Redundant trunk group (RTG)
Compatible with Per-VLAN Spanning Tree Plus (PVST+)
Routed VLAN Interface (RVI)
Uplink Failure Detection (UFD)
ITU-T G.8032 Ethernet Ring Protection Switching
IEEE 802.1AB: Link Layer Discovery Protocol (LLDP)